Camco D-Power 4 User Manual Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
4 OPERATION
USER MANUAL
D - P O W E R S E R I E S
P. 16
D - P O W E R
S E R I E S
4.1 Controls
4.1.1 Volume Control
A volume control with 41 notched settings controls the audio signal. These set-
tings have been selected to correspond to human hearing characteristics (loga-
rithmically) and therefore guarantee an optimal range of settings for practical
applications. Each channel can be set individually except when operating in
mono modes whereby only channel A is active.
Set the volume to zero before turning on the amplifier to prevent the occur-
rence of sudden high volume levels which may cause damage to your hearing
and/or the speakers.
4.1.2 Gain Selector
A switch on the rear of the D-POWER allows the maximum amplification attain-
able to be set directly in the input stage.
The D-POWER amplifier has a 26 dB and 32 dB
voltage gain setting along with a 1,4 V sensitivity
setting.
4.1.3 Gain and Input Sensitivity
The table shows input sensitivity per channel for a given gain and load. It also
shows the gain for the 1,4 V input sensitivity.
Model 26 dB 32 dB 1,4 V
D-POWER 2
1200 W @ 4 Ω
700 W @ 8 Ω
3,47 V
3,75 V
1,74 V
1,88 V 34,56 dB
D-POWER 3
1600 W @ 4 Ω
915 W @ 8
Ω
4,01 V
4,29 V
2,01 V
2,15 V 35,72 dB
D-POWER 4
1900 W @ 4 Ω
1100 W @ 8
Ω
4,37 V
4,70 V
2,19 V
2,36 V 36,52 dB
4.1.4 Limiter Switch
This switch is located at the rear of D-POWER. It allows you to set the mode of the
limiter. There are three modes. (See 4.3.1 Clip Limiter)
Right position: Middle position: Left position:
Clip Limiter: Fast Clip Limiter: Slow Clip Limiter: Off
Fast attack time Slow attack time Limiter disabled
Page view 16